* All prices incl. VAT plus shipping costs and possible delivery charges, if not stated otherwise.
Sensors
for SOMNOtouch™RESP eco
<
>
Tip
Effort sensor
€374.85*
for SOMNOtouch™ RESP; For differentiation of respiratory events (obstructive/central) the movements of the thorax and abdomen are recorded. The SOMNOtouch™ RESP with integrated effort sensor is applied to the thorax, the piezoresistive effort sensor to the abdomen or vice versa.This sensor is part of the basic equipment of the SOMNOtouch™ RESP for polygraphy. The scope of delivery includes a belt set in size L for thorax and abdomen (circumference approx. 86-134 cm, fleece belt with velcro and click closure). The belts are available in different sizes from XS-XXL.Alternatively, disposable effort belts can be used. Our disposable belts are also available in different sizes from S-XXL.Partial obstructions up to paradoxical breathing (180° phase shift) are analysed and evaluated via the phase position of both effort signals. The phase angle analysis determines partial obstructions of adjustable size and duration (flow limitation) and subsequent arousal reactions.The sum of both effort signals can be included in the evaluation as an additional flow signal.The sensor detects breathing movements especially in the frontal position and can therefore only be used to a limited extent in the prone position. We recommend inductive RIP belts for prone sleepers.
Tip
Pulse oximetry sensor / finger clip, size L
€297.50*
for SOMNOtouch™ RESP / ecofor adultsCable length: 1.3 mFor finger thickness between 12.5 and 25.5 mmMaterial: siliconeThe soft silicone finger clip is reusable. It is available in different sizes (S for finger thicknesses of 7.5-12.5 mm, M for finger thicknesses of 10-19 mm, L for finger thicknesses of 12.5-25.5 mm). As an alternative to the silicone finger clip, disposable SpO2 sensors (e.g. Flexi Wrap or Soft Wrap) can also be used.To determine the desaturations, the SpO2 values are averaged over a maximum of 4 beats. The measuring range for oxygen saturation is 70-100% and for the pulse rate 30-240 bpm, the accuracy is ± 3% and ± 3bpm respectively.The basal oxygen saturation as well as the number of desaturations (index) are determined. The desaturations provide information about hypopnea, among other things. The size of the desaturation is adjustable depending on the selected evaluation standard. Changes in the peripheral pulse wave are used to determine autonomic arousals.The time from the end of a respiratory event until the oxygen saturation rises again is determined as the circulation time and can be interpreted in terms of cardiac dysfunction.The R-spike of the ECG and the peripheral pulse wave can be used to calculate the pulse transit time (PTT), the PWV and thus the continuous blood pressure (optional).
Soft Silicone Finger Sensor - peadiatric
€374.85*
for SOMNOtouch™ RESP and SOMNOtouch™ NIBP For finger thicknesses between 7.5 and 12.5 mmCable length 1 m- made of siliconeFor determining oxygen saturation, pulse rate and plethysmogram
Finger Sensor for SOMNOtouch™ RESP
€297.50*
for SOMNOtouch™ RESP / ecofor adults and childrenCable length: 1.3 mFor finger thickness between 10 and 19 mmMaterial: siliconeThe soft silicone finger clip is reusable. It is available in different sizes (S for finger thicknesses of 7.5-12.5 mm, M for finger thicknesses of 10-19 mm, L for finger thicknesses of 12.5-25.5 mm). As an alternative to the silicone finger clip, disposable SpO2 sensors (e.g. Flexi Wrap or Soft Wrap) can be used.To determine the desaturations, the SpO2 values are averaged over a maximum of 4 beats. The measuring range for oxygen saturation is 70-100% and for the pulse rate 30-240 bpm, the accuracy is ± 3% and ± 3bpm respectively.The basal oxygen saturation as well as the number of desaturations (index) are determined. The desaturations provide information about hypopnea, among other things. The size of the desaturation is adjustable depending on the selected evaluation standard. Changes in the peripheral pulse wave are used to determine autonomic arousals.The time from the end of a respiratory event until the oxygen saturation rises again is determined as the circulation time and can be interpreted in terms of cardiac dysfunction.The R-spike of the ECG and the peripheral pulse wave can be used to calculate the pulse transit time (PTT), the PWV and thus the continuous blood pressure (optional).
SoftWrap Finger Sensor for SOMNOtouch™ RESP
€345.10*
for SOMNOtouch™ RESPfor adults and pediatricsincl. 1x SoftWrapCable length: 1.3 mTo record the desaturations, the SpO2 values are averaged over a maximum of 4 beats. The measurement range for oxygen saturation is 70-100% and for the pulse rate 30-240 bpm, the accuracy ± 3% or ± 3bpm.The basal oxygen saturation as well as the number of desaturations (index) are determined. The desaturations provide information about hypopnea, among other things. The size of the desaturation is adjustable depending on the selected evaluation standard. Changes in the peripheral pulse wave are used to determine autonomic arousals.The time from the end of a respiratory event until the oxygen saturation rises again is determined as the circulation time and can be interpreted in terms of cardiac dysfunction.The R-spike of the ECG and the peripheral pulse wave can be used to calculate the pulse transit time (PTT), the PWV and thus the continuous blood pressure (optional).